Tuesday 3 November 2015

30Ma rcd bathroom light

So I have bought a new light fitting for our shower room (This is the bulb.) On the instructions it says if fitting in a bathroom a 30mA RCD is required. Perfect For Your Home Or Garden! Dear DIYnot, I wish to install Zone designed downlighters over bath and understand I need a 30ma RCD in the lighting circuit for proper protection. Perhaps breaking in to the lighting circuit and installing an rcd fused spur to cover the bathroom light (so the rest of the lights are non rcd)and other equipment on the bathroom lighting (fan,shaver light etc), shower on rcd.


Do I need to move both the light rings circuits (upstairs and down) onto the rcd side to stop this one switch from tripping the rcd.

A fault to earth on an RCD protected socket will cause the 30mA RCD to operate first, preventing the loss of supply to the whole installation. Types of RCD There are different types of RCD , that respond to varying types of earth fault current, which need to be selected depending on the type of installation. However, all bathroom services must be protected by a 30mA RCD. All new or additions including a new extractor fan, must conform to these requirements, whether out not it needs earth. Whether it needs earth or not depends on what the manufacturer says.


A RCD protection and current using equipment (other than fixed current using equipment – such as a washing machine, if suitable for use in a bathroom, connected through a fused connection unit) in zone required 30mA RCD protection. Of course once the earth fault current reaches 30mA the RCD will trip, but in the 30ms or so that it takes to trip, the current may well increase to much higher levels, hence you can feel the shock when 30mA is apparently imperceptible to humans. Suitable for bathroom zone if used in conjunction with a 30mA RCD.

IPso suitable for bathroom zone or zone with a 30MA RCD. Supplied with a pull cord switch. IP44: This type of fitting withstands splashing and is commonly used in bathrooms and outdoor lighting.


Feel good about your bathroom lighting by adding floor lights, ceiling lights and wall lights. Combine one light with another to ensure full coverage or brighten up certain areas to create a particular mood - exactly as you want it. If the light uses a 240V supply, a 30ma RCD ( residual current device ) must be used to protect the circuit in this zone. For a contemporary vibe in your bathroom take a look at the Mashiko Classic 3Wall Light – Polished Chrome. An RCD , or residual current device , is a life-saving device which is designed to prevent you from getting a fatal electric shock if you touch something live, such as a bare wire.


It can also provide some protection against electrical fires. RCDs offer a level of personal protection that ordinary fuses and circuit-breakers cannot provide. All circuits in a bathroom should be protected by a 30ma RCD (Residual Circuit Device). Although this is now common practice and is a requirement of Part P of the Building Regulations it is worth double checking especially in older buildings.


A residual current device such as the Rcd fused spurs and Rcd plugs are life saving pieces of kit, they are designed to prevent getting a fatal electric shock if something live like a bare wire is touched. Using the portable rcd plugs which plug into a standard socket the protection has been added and the appliance can be plugged into the Rcd. We supply trade quality DIY and home improvement products at great low prices. Two additional things to consider - the requirement for an RCD protecting the circuit(s) into bathroom , and IP rating for light fittings to protect against moisture.


As this sounds like a new circuit - or an extension to existing - it is highly recommended you get a qualified electrician in.

Sleek curved LED shaver light with an opal polycarbonate and white acrylic finish. The popular Portico LED bathroom ceiling light features frosted glass and chromel finish. This fitting can also be wall mounted if preferred and comes complete with LED driver. Bathroom Wall Lights product range. The bathroom is the most dangerous room in the home because when your skin is wet it’s extremely sensitive to electric current.


Dry hands thoroughly before handling an appliance, and never use one that is damaged. IPrated ensuring protection against the intrusion of water. All switches and outlets in a bathroom must be protected by a 30mA Residual Current Device ( RCD ). Buy this Hager Hager RCD pole 100A AC, 30mA current rating, Hager CD484U RCCB CD484U online from Sparks Direct at our low price of £204.


This light fitting must be connected to the supply earth. If your lighting circuit does not have an earth, ask a qualified electrician to provide an earth facility. Find out more with our guide to bathroom lighting installation.


Let us help you transform your bathroom. Find the ideal lighting system for your home today. Other than that you could use other cables that under the requirements do not need additional protection, and so do not need to be rcd protected.


Up to press I have had no problems with the device the adapter has functioned as it should. I would recommend the device for all household electrical jobs i. Water jet spraying, heater appliances. Often the simplest option for bathroom lights is a single flush ceiling light utilising cfl, fluorescent or LED bulbs.